1.3.3.1 (Sept 2025) - OS and App Release
- Switched to the DSP rev. 12.6. This will improve issues with the ambient noise sensor calibration and support the new delays
- Fixed the loading of the EQ frequencies.
- Add event logging (similar to the MicStation). This saves T112 app Startup/Shutdown/Crash/Update/Restart/... events to permanent file.
- Add a T112 app restart if the DSP is locked up for more than 60 seconds.
- Change the CobraNet reset logic to reset the entire T112 app.
- Change CobraNet lockup detection to not send a SNMP message if address is 0.0.0.0.
- Add more info to the T112Event.log for CobraNet lockup messages and factory reset.
- Created a T112 update package to cleanup the BGM compressor issue (from version 1.3.0.0).
- Fixed the issue of the app crashing during the first boot after a factory reset (the root cause of the BGM issue)
- Fix timer rollover issues when the time changed to any time in the past (for HardwareController, DspMessenger, FramSupervisor, AudioSupv, and AmbientSensorSupv)
- Fix the frame fault offset issue for GCK. The fault would show as the wrong type.